COMPRO U700 - START UP GUIDE Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Non COMPRO U700 - START UP GUIDE. COMPRO U700 - START UP GUIDE Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
HBC - SERIES V7
Low Voltage (63V), small types
Programmable brushless controllers for industry using
Operating Manual firmware version 3.8 or higher
Development, manufacture, service: Tel.: +420 577 001 350
MGM COMPRO, Ing. G. Dvorský E-mail: mgm@mgm-compro.cz
Sv. Čecha 593, 760 01 Zlín, Czech Republic Info: www.mgm-compro.com
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - HBC - SERIES V7

HBC - SERIES V7 Low Voltage (63V), small types Programmable brushless controllers for industry using

Page 2 - xxxx – 3 HBC-series V7

10 / 60 HBC-series V7 LV small types profi low power Marking and Specification of the HBC controllers / allowed combination Marking of HBC_AAA

Page 3 - Table of content:

11 / 60 HBC-series V7 LV small types profi low power Basic controller connection Note 1: Both inp

Page 4 - Basic Recommendations

12 / 60 HBC-series V7 LV small types profi low power Connecting controller to the traction supply and turning on Note: Power

Page 5 - HBC-series TMM

13 / 60 HBC-series V7 LV small types profi low power Control signals specification Controller can be driven (depend on the customer specificatio

Page 6 - MGM COMPRO

14 / 60 HBC-series V7 LV small types profi low power Control by data transfer. When controlling is realized by data transfer, following possibil

Page 7 - 001 350

15 / 60 HBC-series V7 LV small types profi low power Control by potentiometer. In case, potentiometer is connect by longer cable (>20 cm), w

Page 8

16 / 60 HBC-series V7 LV small types profi low power Control and additional control by logic signals Control by logic signal (function A). The

Page 9

17 / 60 HBC-series V7 LV small types profi low power Cooperation with RC Remote Control When you need or is necessary used industry version of t

Page 10

18 / 60 HBC-series V7 LV small types profi low power Control signal – correct limits and emergency conditions Controller monitors presence of dr

Page 11

19 / 60 HBC-series V7 LV small types profi low power Control by input PWM: Here is similar situation. When lost signal from driving PWM generato

Page 12

2 / 60 HBC-series V7 small power Small programmable brushless controllers for industry using TMM® xxxx – 3 HBC-series V7 These motor speed c

Page 13

20 / 60 HBC-series V7 LV small types profi low power Connect to corresponding connector of transmitting module 2.4 GHz Display unit for displayin

Page 14 - (1 or 2)

21 / 60 HBC-series V7 LV small types profi low power Sensor motors and controllers Sensor motors (BLDC motors with sensors) can have generally d

Page 15

22 / 60 HBC-series V7 LV small types profi low power Example: Motor by NOVAK, Velocity 3.5R Brushless Motor Phase A Phase C Phase B conne

Page 16

23 / 60 HBC-series V7 LV small types profi low power Optimal and allowed motor sensor position Next picture displayed correct relative position

Page 17

24 / 60 HBC-series V7 LV small types profi low power Basic operating modes - mode choice and basic type of behavior The regulator has a preset s

Page 18 - - series

25 / 60 HBC-series V7 LV small types profi low power One-way Car brake is on a separate channel . The throttle is controlled by

Page 19 - - series Controller

26 / 60 HBC-series V7 LV small types profi low power Programmable parameters Parameters setting by user, including default values for all memory

Page 20 - - batt

27 / 60 HBC-series V7 LV small types profi low power Parameter Table continue Legend: H - choice from discrete values With respect to possibil

Page 21

28 / 60 HBC-series V7 LV small types profi low power Description of all parameters Memory bank – memory choice (choice of pre-defined paramet

Page 22

29 / 60 HBC-series V7 LV small types profi low power P4: Control signal Driving signal can be: - input PWM (pulse width 1 ÷ 2 ms, period 3.5 ÷

Page 23

3 / 60 HBC-series V7 LV small types profi low power Table of content: Table of content: ...

Page 24

30 / 60 HBC-series V7 LV small types profi low power P6, P7, P8: Joystick limits, range of control signal – values for Main channel (values in

Page 25 - Memory select

31 / 60 HBC-series V7 LV small types profi low power P42: Controller feeding (Type of cells / switching-off voltage) Parameter set type of cells,

Page 26 - Programmable parameters

32 / 60 HBC-series V7 LV small types profi low power P87: "Empty battery" in advance warning by charge (alarm when battery charge drops

Page 27 - MGM COMPRO company please

33 / 60 HBC-series V7 LV small types profi low power P52: Motor timing (value in ° (angle in degrees)) Automatic timing or 0° is recommended s

Page 28

34 / 60 HBC-series V7 LV small types profi low power P16: Acceleration, increasing of the power (rpm), time from 0% power to 100% (values in mil

Page 29

35 / 60 HBC-series V7 LV small types profi low power P82: Cruise controls Ramp (values in seconds) Sets the rate of reaction speed at which the c

Page 30

36 / 60 HBC-series V7 LV small types profi low power P38: Control signal lost masking

Page 31 - / cell

37 / 60 HBC-series V7 LV small types profi low power P71: BB data logging period (Internal BlackBox record period) / real time Monitoring The

Page 32

38 / 60 HBC-series V7 LV small types profi low power P36: Calibration of the battery temperature sensor (value in °C) For easy replacement of the

Page 33 - P83 = 15%

39 / 60 HBC-series V7 LV small types profi low power View from opposite side to USB port in PC connector ICS-2 CC_11 Connection cable CC_11 EFRA

Page 34

4 / 60 HBC-series V7 LV small types profi low power First steps First, before you start run controller, we recommend read Basic Recommendations

Page 35

40 / 60 HBC-series V7 LV small types profi low power Locks of parameters If you need for parameters that you set (only some or even all) the use

Page 36

41 / 60 HBC-series V7 LV small types profi low power Unlocked parameter, you can change its value Locked parameters are displayed, but they cann

Page 37 - Record Stop:

42 / 60 HBC-series V7 LV small types profi low power Internal Black Box (flying recorder) – data logger For correct using of controller’s Black

Page 38

43 / 60 HBC-series V7 LV small types profi low power The right vertical axis (scale) The left vertical axis (sc

Page 39 - Connection cable CC_11

44 / 60 HBC-series V7 LV small types profi low power Evaluation (interpretation) parts of the record: For greater clarity, the color and scale

Page 40 - Locks of parameters

45 / 60 HBC-series V7 LV small types profi low power Data stored in the record to an internal Black Box / The data displayed in real time (Monit

Page 41

46 / 60 HBC-series V7 LV small types profi low power Monitoring (display data in real time) If you need monitor the values of individual variabl

Page 42

47 / 60 HBC-series V7 LV small types profi low power Throttle limits settings (range of joystick, range of control signals) To respond the cont

Page 43

48 / 60 HBC-series V7 LV small types profi low power b) By control signal source - set corresponding limits at any time direct by the signal so

Page 44

49 / 60 HBC-series V7 LV small types profi low power NEUTRÁL Full throttle forward Full throttle backward NEUTRÁL Min. throttle Full throttl

Page 45

5 / 60 HBC-series V7 LV small types profi low power Technical data (valid for 25°C environment temperature) (valid for control board EF5) Temper

Page 46 - Monitored data:

50 / 60 HBC-series V7 LV small types profi low power NEUTRAL = STOP MIN = STOP Start with programmed throttle limits a) Type of controller’s

Page 47 - PREFERED WAY:

51 / 60 HBC-series V7 LV small types profi low power Maximal revolution of the output shaft Settings For setting of Maximal revolution of unloa

Page 48

52 / 60 HBC-series V7 LV small types profi low power Update SW inside the controller (firmware) When you want make update firmware in you contr

Page 49

53 / 60 HBC-series V7 LV small types profi low power 8a 8b. when procedure corrupt (communication er-ror etc.), is displayed this message Necess

Page 50 - STOP position

54 / 60 HBC-series V7 LV small types profi low power SW before update Installation and run program Controller 2 Are very simply and intuitive.

Page 51 - MRM = KV x U

55 / 60 HBC-series V7 LV small types profi low power melody♪ ♪ ♪ ♪ short beep  long beeeep Controller states indication, Error messages (

Page 52

56 / 60 HBC-series V7 LV small types profi low power Sparking prevent when connect higher voltage When connecting a Li-xxx pack to the controll

Page 53

57 / 60 HBC-series V7 LV small types profi low power Additional information Influence of the battery quality to controller behavior (automatic

Page 54

58 / 60 HBC-series V7 LV small types profi low power Some of Protective and Safety mechanisms of TMM® controllers Controllers mask interference

Page 55 -  long beeeep

59 / 60 HBC-series V7 LV small types profi low power Indication module BL_04D Extended cable EC_2 to ICS-2 connector Indication module BL_04D -

Page 56 - Ω- 100Ω

6 / 60 HBC-series V7 LV small types profi low power *) Maximal continuous (nominal) current: Maximal continuous current, without any time lim

Page 57 - Additional information

60 / 60 HBC-series V7 LV small types profi low power Content of delivery  Controller in box  3 antispark resistors  CD with program Contro

Page 58 - controllers

7 / 60 HBC-series V7 LV small types profi low power Regular controller without coolers, controlling by voltage (potentiometer), with switch 452

Page 59

8 / 60 HBC-series V7 LV small types profi low power Version with cooler (heatsink) for controllers 4526-3, 6026-3, 5035-3, 5063-3 WR version Vers

Page 60 - Recycling